    PSA Oxygen Enrichment for Industrial Supply

    PUFCO PSA oxygen generators use zeolite molecular sieves to separate nitrogen from prepared compressed air, delivering an oxygen-enriched stream. Adsorption vessels alternate between production and regeneration under programmable control. Pneumatic valve sequencing coordinates the cycle, with upstream air treatment and downstream buffering planned as part of the system.

    Coordinate Generation, Monitoring and Delivery

    The proposed system is matched to the required oxygen composition, usable output and delivery conditions. Configured instrumentation helps operators follow production parameters. If the project includes high-pressure storage or cylinder filling, separate oxygen boosting and receiving equipment must be selected alongside the generator for the intended industrial duty.

    Core Design

    • Zeolite molecular sieve oxygen-enrichment process
    • Alternating PSA production and regeneration
    • Programmable control with pneumatic valve sequencing

    Configuration and Selection

    • Required oxygen composition and production output
    • Feed-air treatment, buffering and monitoring scope
    • Delivery pressure and separately matched boosting equipment

    Share the industrial application, oxygen specification and delivery requirements when requesting a complete system proposal.

    Why choose our air compressor solutions

    On-Site Oxygen Enrichment

    Zeolite molecular sieve selectively adsorbs nitrogen from prepared compressed air, producing an oxygen-enriched stream on site for an industrial process with a defined gas specification.

    Alternating PSA Production

    Adsorption vessels alternate between oxygen production and regeneration, coordinating the separation cycle so the installation can supply gas through its selected operating and buffering arrangement.

    Automated Valve Sequencing

    Programmable control operates the pneumatic valve sequence, coordinating pressurization, adsorption and depressurization steps and reducing the manual intervention required to manage the normal PSA cycle.

    Production Parameter Visibility

    Configured instruments make oxygen purity, flow and operating status available to operators, supporting routine supervision of the gas-generation process and comparison with the specified downstream demand.

    Prepared Air And Buffering

    Air purification ahead of the generator and an oxygen buffer downstream support a coordinated supply arrangement, with equipment scope matched to the chosen production capacity and usage pattern.

    Optional Remote Monitoring

    Optional IoT functionality enables remote monitoring and data analysis from a computer or mobile terminal. This gives the team another way to follow generator operation beyond the local control interface.

    PSA Oxygen Generator
    ModelProduction
    (Nm³/h)
    Effective Gas Volume
    (Nm³/min)
    PurityPressure
    (Mpa)
    Dew Point
    (℃)
    Inlet Diameter
    (mm)
    Outlet Diameter
    (mm)
    PBN-550.9228–95.0%0.1–15Mpa-42 to -702515
    PBN-10101.8528–95.0%0.1–15Mpa-42 to -703215
    PBN-15152.7528–95.0%0.1–15Mpa-42 to -703215
    PBN-20203.728–95.0%0.1–15Mpa-42 to -704015
    PBN-30305.528–95.0%0.1–15Mpa-42 to -704015
    PBN-40407.328–95.0%0.1–15Mpa-42 to -705025
    PBN-50509.228–95.0%0.1–15Mpa-42 to -705025
    PBN-60601128–95.0%0.1–15Mpa-42 to -705025
    PBN-808014.628–95.0%0.1–15Mpa-42 to -706532
    PBN-10010018.528–95.0%0.1–15Mpa-42 to -706532
    PBN-15015027.528–95.0%0.1–15Mpa-42 to -708040
    PBN-20020036.728–95.0%0.1–15Mpa-42 to -7010040
    PBN-3003005528–95.0%0.1–15Mpa-42 to -7012550
    PBN-40040073.328–95.0%0.1–15Mpa-42 to -7012550
    PBN-50050091.628–95.0%0.1–15Mpa-42 to -7015050

    A PSA oxygen generator is an option for on-site oxygen supply where the process can use the composition, flow and pressure delivered by the selected system. It can serve as the oxygen source for an engineered cylinder-filling installation with suitable buffering, a separate oxygen booster and rated filling equipment. Required gas quality, supply continuity and monitoring must be defined for the complete project; generator outlet pressure should not be treated as cylinder-filling pressure.

    Frequently Asked Questions

    • Q1: What backup supply is needed if the oxygen generator stops?

      ▼

      A1: If oxygen supply must continue during a generator outage, provide an independently available backup source sized for the required flow and interruption time. Buffer storage may cover short demand changes, but its usable capacity is finite. The backup source, changeover controls and monitoring must be specified for the complete system and included explicitly in the agreed scope.

    • Q2: Does the generator directly deliver cylinder filling pressure?

      ▼

      A2: Cylinder filling requires a separate oxygen booster when the filling pressure exceeds the generator's specified outlet pressure. The generator produces oxygen, while the booster raises its pressure. Confirm generator outlet conditions, buffer storage, booster capacity and filling-equipment scope for the proposed system.

    • Q3: Why is compressed air treatment required?

      ▼

      A3: Compressed-air treatment removes oil, water and other impurities before they enter the oxygen generator's molecular sieve beds. The feed air must meet the selected generator's specified limits. Size the treatment equipment for actual inlet conditions and flow, and confirm the required inspection and maintenance schedule.

    • Q4: How should oxygen output be specified?

      ▼

      A4: State the required gas composition, production flow at defined reference conditions, outlet pressure and operating schedule together. A production flow without its associated quality and delivery conditions is not a complete selection specification.

    • Q5: Does PSA oxygen generation automatically meet medical requirements?

      ▼

      A5: No. PSA (pressure swing adsorption) alone does not establish medical suitability. A healthcare project requires verification of the specified gas quality, equipment documentation and complete supply system for the intended use and destination market. Confirm those requirements before describing an oxygen supply as medical-grade.

    Have more questions about this product? Click the chat icon in the bottom-right corner to contact our team.

    Get a Free Quote

    Our representative will contact you soon.

      Add company, phone or an attachment (optional)

      One file, up to 10 MB. Images, documents, CAD files or ZIP.

      Get a Free Quote

      Our representative will contact you soon.

        Add company, phone or an attachment (optional)

        One file, up to 10 MB. Images, documents, CAD files or ZIP.

        Get a Free Quote

        Our representative will contact you soon.

          Add company, phone or an attachment (optional)

          One file, up to 10 MB. Images, documents, CAD files or ZIP.

          email