Get a Free Quote

Our representative will contact you soon.

    Add company, phone or an attachment (optional)

    One file, up to 10 MB. Images, documents, CAD files or ZIP.

    PLC-controlled oil-free oxygen compressor

    1.PLC Intelligent Control Version

    2.Suitable for Small Hospitals

    3.Easy Operation

    4.Completely Oil-Free, Safe and Reliable

    • Overview
    • Product Advantages
    • Technical Parameters
    • Application Scenarios
    • FAQ

    PLC Supervision for Staged Oxygen Boosting

    The PUFCO PLC-controlled oil-free oxygen compressor combines staged pressure boosting with centralized machine control. Pressure and temperature information helps operators follow the compression process and respond to detected abnormal conditions. The oil-free compression chamber keeps lubricating oil away from oxygen during the pressure-boosting step.

    Coordinate the Compressor with Your Oxygen System

    The package is selected around the available oxygen source and the receiving system. Compression arrangement, motor choice and electrical supply are considered together with cooling and installation requirements. A compact layout with base handling positions helps project teams plan delivery and equipment placement within the installation.

    Core Design

    • PLC combines operating information and control in one arrangement.
    • Staged compression divides the required pressure rise across the machine.
    • Pressure and temperature protection supports alarm and shutdown functions.

    Configuration and Selection

    • Match source conditions with required delivery pressure and flow.
    • Specify motor selection and the available electrical power supply.
    • Confirm cooling, control interfaces and installation requirements for the model.

    For a proposal, send oxygen-source conditions, required flow, delivery pressure and site power supply.

    Why choose our air compressor solutions

    PLC Process Monitoring

    The PLC control package brings operating information and machine control together. Pressure and temperature monitoring help operators supervise oxygen boosting and respond to detected abnormal operating conditions.

    Staged Oxygen Compression

    The four-stage arrangement divides the pressure rise across successive compression stages. Stage-by-stage compression provides a structured pressure-boosting process for oxygen filling duties and the specified delivery requirement.

    Oil-Free Compression Chamber

    The oil-free compression chamber keeps lubricating oil out of the oxygen gas path. This reduces the risk of added oil contamination when transferring gas from the source to the receiving system.

    Pressure And Temperature Protection

    Stage relief valves, temperature sensors and inlet and discharge pressure monitoring work with alarm and shutdown functions. Together, these features help detect and respond to abnormal compression conditions.

    Compact Handling Layout

    A compact footprint helps organize the equipment area, while forklift positions at the base support handling. These provisions simplify planning the delivery route and positioning the compressor during installation.

    Project-Matched Configuration

    Compression arrangements and motor selection can be matched to the required oxygen duty. Project-specific configuration helps coordinate the compressor with the source, electrical supply and planned installation conditions.

    PLC-controlled oil-free oxygen compressor
    ModelWorking mediumIntake pressure
    (barg)
    Exhaust pressure
    (barg)
    Nominal volumetric flow rate
    (NM3/H)
    Power
    (kw)
    Intake/Exhaust
    Port
    Cooling methodweight
    (kg)
    Size
    (mm)
    Compression level
    POW-4/4-150Oxygen4572015043DN15/DN6Air-Cooling3201000×750×10504
    POW-5/4-150Oxygen4572015053DN15/DN6Air-Cooling3201000×750×10504
    POW-6/4-150Oxygen4572015063DN15/DN6Air-Cooling3201000×750×10504
    POW-8/4-150Oxygen4572015084DN15/DN6Air-Cooling3301000×750×10504
    POW-10/4-150Oxygen45720150105.5DN15/DN6Air-Cooling3401000×750×10504
    POW-12/4-150Oxygen45720150125.5DN15/DN6Air-Cooling3401000×750×10504

    A PLC-controlled oil-free oxygen compressor can be integrated with a PSA oxygen generation system to raise gas pressure for an engineered cylinder-filling installation. This configuration suits projects that require pressure and temperature monitoring with defined alarm and shutdown responses. Match the oxygen source flow and inlet pressure to the filling schedule, and specify the buffer storage, filling manifold and control interfaces as part of the complete installation.

    Frequently Asked Questions

    • Q1: What does PLC control cover on this oxygen compressor?

      ▼

      A1: The PLC (programmable logic controller) monitors pressure and stage temperatures and triggers alarms or shutdowns when configured limits are exceeded. The order specification should identify the inlet and discharge pressure protection, stage safety valves, alarm limits and shutdown sequence. These functions must be defined for the selected model; PLC control alone does not establish the complete protection package.

    • Q2: Can this compressor work with my PSA oxygen generator?

      ▼

      A2: It can be considered only if the generator's oxygen composition, flow and delivery pressure meet the compressor's inlet requirements throughout operation. PSA means pressure swing adsorption, a gas separation process. Check generator controls, any buffer tank and the downstream filling demand together before selecting the compressor.

    • Q3: How do I size an oxygen compressor for cylinder filling?

      ▼

      A3: Size it for the gas required to fill the planned cylinders within the available time, using the compressor's delivery at the actual inlet and final filling pressures. Supply the cylinder sizes, starting and target pressures, number of cylinders and filling schedule, together with the oxygen source's available flow. A high discharge-pressure rating alone does not establish filling capacity.

    • Q4: Does PLC control mean remote monitoring is included?

      ▼

      A4: PLC control does not by itself define remote access or a particular communication protocol. Specify the required signals, supervisory system and interface so any communication functions can be included in the agreed package.

    • Q5: What oxygen quality information do you need for compressor selection?

      ▼

      A5: Specify the oxygen source composition, required gas quality at the delivery point, intended use and destination market. The compressor and complete supply arrangement must be assessed against those requirements, with the applicable equipment and gas quality documentation confirmed for the project.

    Have more questions about this product? Click the chat icon in the bottom-right corner to contact our team.

    Get a Free Quote

    Our representative will contact you soon.

      Add company, phone or an attachment (optional)

      One file, up to 10 MB. Images, documents, CAD files or ZIP.

      Get a Free Quote

      Our representative will contact you soon.

        Add company, phone or an attachment (optional)

        One file, up to 10 MB. Images, documents, CAD files or ZIP.

        Get a Free Quote

        Our representative will contact you soon.

          Add company, phone or an attachment (optional)

          One file, up to 10 MB. Images, documents, CAD files or ZIP.

          email