Get a Free Quote

Our representative will contact you soon.

    Add company, phone or an attachment (optional)

    One file, up to 10 MB. Images, documents, CAD files or ZIP.

    Dry Type Screw Vacuum Pump

    1.Uses two synchronously rotating screws operating in opposite directions to generate vacuum suction and exhaust.

    2.Precisely balanced screws maintain a fixed clearance, enabling friction-free operation.

    3.Delivers stable performance with low noise and vibration.

    4.Oil-free working chamber, ensuring clean operation and minimal maintenance.

    • Overview
    • Product Advantages
    • Technical Parameters
    • Application Scenarios
    • FAQ

    Dry Screw Pumping Without Chamber Sealing Oil

    PUFCO dry screw vacuum pumps move gas through a pumping chamber using synchronized, counter-rotating screws. Controlled clearances keep the rotors from contacting each other during normal operation. The pumping chamber needs no sealing oil, providing a dry gas path for processes that must avoid oil-sealed vacuum operation.

    Cooling and Process Conditions Designed Together

    A water-cooled jacket removes heat from the pump body, while the continuous helical gas path supports gas transfer through the pumping element. The pump can also serve as a backing unit for compatible vacuum equipment. Gas composition, condensable load and required working pressure guide the proposed arrangement.

    Core Design

    • Synchronized screws with controlled rotor clearances
    • Pumping chamber without sealing oil
    • Water-jacket cooling and a continuous gas path

    Configuration and Selection

    • Working pressure and effective pumping speed
    • Gas composition and condensable load
    • Cooling-water conditions and compatible system connections

    Share your process gas, working pressure and cooling-water conditions when requesting a dry screw vacuum pump proposal.

    Why choose our air compressor solutions

    Oil-Free Pumping Chamber

    The pumping chamber requires no sealing oil, keeping that oil out of the process gas path and simplifying oil-related considerations for downstream gas handling.

    Non-Contact Screw Motion

    Synchronized screw rotors run with controlled clearances rather than rubbing against each other, reducing direct rotor contact within the pumping chamber during normal operation.

    Water-Jacket Heat Control

    A cooling-water jacket removes heat from the pump body, giving the vacuum installation a defined heat-rejection path when the specified water conditions are available.

    Continuous Helical Gas Path

    Helical rotors move gas through a continuous pumping path without intermediate partition stages, simplifying the gas-transfer arrangement within the screw vacuum pumping mechanism itself.

    Simplified Internal Arrangement

    A non-contact rotor arrangement with fewer internal components supports service access and maintenance planning, helping users manage the pump as part of a process vacuum installation.

    Flexible Vacuum-System Integration

    The pump can serve as a backing unit for compatible Roots or molecular pump arrangements, allowing different vacuum stages to be coordinated around the required process duty.

    Dry Type Screw Vacuum Pump
    ModelPumping rate
    (m³/hr)
    Ultimate vacuum(Pa)Power
    (kW)
    rotational speed(rpm)Import(mm)Export(mm)cooling water(L/min)Weight(kg)Oil(L)Size (LWH,mm)
    PDSV180 50Hz18027.5290065502.53350.851200*400*780
    PDSV180 60Hz21617.53550
    PDSV250 50Hz25027.5290065502.53350.851200*400*780
    PDSV250 60Hz30017.53550
    PDSV250 50Hz25027.5290080802.63450.851243*400*780
    PDSV250 60Hz30017.53550
    PDSV400 50Hz40027.5290080502.53450.851243*400*780
    PDSV400 60Hz4801113550
    PDSV400 50Hz4002112900100802.86101.41547*490*1147
    PDSV400 60Hz4801153550
    PDSV540 50Hz540218.5290015080367521538*530*1095
    PDSV540 60Hz650118.53550
    PDSV580 50Hz5802152900100802.66101.41547*490*1147
    PDSV580 60Hz7001153550
    PDSV720 50Hz720222290015080496521760*600*1200
    PDSV720 60Hz8501223550
    PDSV800 50Hz800218.52900150802.867521538*530*1095
    PDSV800 60Hz9601223550
    PDSV1000 50Hz1000100222900150802.867521538*530*1095
    PDSV1000 60Hz1200200223550
    PDSV1080 50Hz108050222900150802.867521538*530*1095
    PDSV1080 60Hz129030223550
    PDSV1080 50Hz1080503029001501005100021760*600*1200
    PDSV1080 60Hz129030373550
    PDSV1200 50Hz120023029001501003.5100021760*600*1200
    PDSV1200 60Hz14401373550

    A dry screw vacuum pump is an option for process-vessel evacuation, vacuum drying and degassing where the pumping chamber must operate without sealing oil. It can also form the backing stage of a compatible Roots or molecular-pump system. Gas composition, vapor release and operating pressure determine the required configuration; condensation control, inlet protection and cooling-water provision must suit the process, especially when the gas is corrosive or can deposit solids.

    Frequently Asked Questions

    • Q1: Does dry screw operation mean the entire pump contains no oil?

      ▼

      A1: No. Dry describes the pumping chamber, where sealing oil is not required. Lubrication requirements elsewhere in the assembly must be confirmed for the selected model, including the correct lubricant and maintenance procedure.

    • Q2: What cooling utilities does the pump need?

      ▼

      A2: The pump uses jacket cooling, and cooling-water flow varies by model. Confirm the required water quality, inlet temperature, flow and pressure for the exact unit before finalizing the installation.

    • Q3: Can it handle corrosive or flammable process gases?

      ▼

      A3: Only if the selected materials, seals and protection measures are suitable for the exact gas mixture and operating conditions. Provide the gas composition, concentration, temperature and any condensable components for compatibility review. Flammable service also requires confirmation of the relevant hazardous-area requirements and the proposed equipment configuration.

    • Q4: Can a dry screw pump serve as a backing pump?

      ▼

      A4: A dry screw pump can be considered as a backing pump when its pumping capacity and pressure range match the main pump’s requirements. A backing pump maintains the outlet pressure needed by a Roots or molecular pump. Check gas throughput, startup sequence, cooling and process-gas compatibility for the complete combination.

    • Q5: How should I specify the required vacuum performance?

      ▼

      A5: Provide the working absolute pressure, measured relative to a perfect vacuum, together with gas throughput and the evacuation cycle. Request model-specific performance data at that operating point, including the effects of electrical frequency and cooling conditions. Ultimate pressure alone cannot determine the useful pumping capacity.

    Have more questions about this product? Click the chat icon in the bottom-right corner to contact our team.

    Get a Free Quote

    Our representative will contact you soon.

      Add company, phone or an attachment (optional)

      One file, up to 10 MB. Images, documents, CAD files or ZIP.

      Get a Free Quote

      Our representative will contact you soon.

        Add company, phone or an attachment (optional)

        One file, up to 10 MB. Images, documents, CAD files or ZIP.

        Get a Free Quote

        Our representative will contact you soon.

          Add company, phone or an attachment (optional)

          One file, up to 10 MB. Images, documents, CAD files or ZIP.

          email