Oil-Free Scroll Vacuum Pump
Pumping speed: 4m³/h to 60m³/h;
High vacuum: Ultimate vacuum down to 1Pa;
Fully oil-free: No oil return, no oil spray;
Start-stop capability: Frequent cycling between atmospheric pressure and vacuum;
Quiet operation: Low noise, low vibration;
Compact design: Small footprint, lightweight.
- Overview
- Product Advantages
- Technical Parameters
- Application Scenarios
- FAQ
- Stationary and orbiting scroll pumping elements
- Pumping chamber without sealing oil
- Compact air-cooled equipment arrangement
- Working pressure, gas load and evacuation cycle
- Model-matched vacuum connections and motor supply
- Ventilation conditions and required inlet protection
Oil-Free Scroll Pumping in a Compact Layout
PUFCO oil-free scroll vacuum pumps use stationary and orbiting scrolls to create gas chambers that shrink toward the outlet. This progressive pumping action operates without sealing oil in the chamber. The compact layout provides a vacuum source that equipment builders can incorporate into instruments and machinery.
Air Cooling for Repeated Evacuation Duties
An air-cooled arrangement avoids a separate cooling-water connection, provided the installation has suitable ventilation. The scroll mechanism supports evacuation tasks that include repeated start-stop cycles. Pump size, motor configuration and vacuum connections are selected together, with inlet protection reviewed where moisture or particles may enter the system.
Core Design
Configuration and Selection
Tell us your evacuation cycle, target working pressure and electrical supply to select the appropriate scroll pump.
Why choose our air compressor solutions
Oil-Free Vacuum Generation
The scroll pumping chamber works without sealing oil, avoiding the oil changes and oil-return concerns associated with an oil-sealed chamber in the vacuum gas path.
Repeated Evacuation Capability
The scroll design supports repeated evacuation between atmospheric pressure and vacuum, making it a useful configuration for equipment processes that include regular start-stop pumping cycles.
Compact Pump Layout
A compact, lightweight pump assembly helps equipment builders reserve less installation space for the vacuum source and incorporate it into instruments or machinery with constrained layouts.
Air-Cooled Installation
Air cooling avoids a separate cooling-water connection, simplifying utility planning where the installation provides sufficient ventilation and stays within the selected model’s permitted ambient conditions.
Smooth Scroll Pumping
The orbiting scroll progressively compresses gas in crescent-shaped chambers, providing a smooth pumping mechanism that helps limit vibration in equipment using this scroll pump design.
Equipment Connection Options
Model-specific vacuum flanges and available motor configurations help align the pump with the equipment pipework and electrical supply, supporting a planned installation rather than improvised connections.
| Category | Unit | PSV4 | PSV8 | PSV16 | PSV30 | PSV60 | |
| Pumping Speed | 50Hz | L/S | 1 | 2 | 4.3 | 8.7 | 16.6 |
| L/min | 60 | 120 | 258 | 522 | 996 | ||
| m³/h | 3.6 | 7.2 | 15.5 | 31.3 | 59.8 | ||
| cfm | 2.2 | 4.3 | 9.3 | 18.7 | 35.9 | ||
| 60Hz | L/S | 1.2 | 2.4 | 5.1 | 10.4 | 19.8 | |
| L/min | 72 | 144 | 306 | 624 | 1194 | ||
| m³/h | 4.3 | 8.6 | 18.3 | 37.4 | 71.6 | ||
| cfm | 2.5 | 5.1 | 10.9 | 22.3 | 42.8 | ||
| Ultimate Vacuum | Pa | ≤6.0 | ≤6.0 | ≤1.6 | ≤1.0 | ≤1.0 | |
| Torr | ≤6.0×10⁻² | ≤6.0×10⁻² | ≤1.9×10⁻² | ≤7.5×10⁻³ | ≤7.5×10⁻³ | ||
| Psi | ≤1.2×10⁻⁴ | ≤9.0×10⁻⁴ | ≤3.8×10⁻⁴ | ≤1.4×10⁻⁴ | ≤1.4×10⁻³ | ||
| noise | dB(A) | ≤52 | ≤57 | ≤60 | ≤61 | ≤63 | |
| Leakage Rate | Pa·m³/s | 1.0×10⁸ | |||||
| Maximum Inlet/Outlet Pressure | MPa | 0.1/0.13 | |||||
| Work Environmental Temperature | ℃ | 5-40 | |||||
| Cooling Mode | / | Air Cooled | |||||
| Inlet/Outlet Flange | / | KF25/KF16 | KF25/KF16 | KF25/KF16 | KF40/KF16 | KF40/KF16*2 | |
| Single Phase Motor | Power | kW | 0.55 | 0.55 | 0.55 | 0.75 | — |
| Voltage | V | 220-230V/50Hz;110V-115V/60Hz | |||||
| Speed | rpm | 1425(50Hz);1725(60Hz) | |||||
| Three Phase Motor | Power | kW | 0.55 | 0.55 | 0.55 | 0.75 | 1.5 |
| Voltage | V | 220-230V 与 380-415V/50Hz;110V-115V 与 460V/60Hz | |||||
| Speed | rpm | 1425(50Hz);1725(60Hz) | |||||
| Size | Single-Phase | mm | 455×265×295 | 455×265×295 | 485×310×340 | 515×325×355 | — |
| Single-Phase | mm | 455×265×295 | 455×265×295 | 485×310×340 | 515×325×355 | 565×445×405 | |
| Weight | Single-Phase | kg | 21 | 22 | 29 | 36 | — |
| Single-Phase | kg | 20 | 21 | 28 | 31 | 54 | |
| other | / | Pneumatic Ballast Valve | |||||
An oil-free scroll vacuum pump is a candidate for analytical instruments, small vacuum chambers and compact equipment that need to keep sealing oil out of the pumping path. For chambers repeatedly evacuated from atmosphere, the required cycle time must match pumping speed and the permitted operating duty. Instrument integration also needs suitable ventilation and maintenance access, with inlet protection selected for the expected moisture and particles rather than assuming an oil-free chamber removes those contaminants.
Frequently Asked Questions
Q1: What makes a scroll vacuum pump oil-free?
▼A1: The scroll pumping mechanism compresses gas without oil used to seal the working chamber. This removes a source of oil in the gas path, but it does not guarantee that the complete connected system is free of every contaminant.
Q2: Can this scroll pump handle repeated evacuation from atmospheric pressure?
▼A2: The range is designed for repeated evacuation from atmospheric pressure to vacuum, subject to the selected model’s operating limits. Confirm the evacuation time, time between cycles and permitted start-stop sequence for your process. Repeated pump-down capability should not be taken as permission for unlimited motor starts.
Q3: When should I choose a scroll vacuum pump instead of an oil-sealed rotary vane pump?
▼A3: Consider a scroll pump when avoiding sealing oil in the pumping chamber is important and its pumping speed, working-pressure range and gas compatibility suit the process. Compare the two designs at the same duty, including oil handling, inlet protection and scheduled seal servicing. An oil-free chamber does not make a scroll pump maintenance-free or suitable for every process gas.
Q4: How is the pump cooled?
▼A4: The pump is air-cooled. Provide the specified ambient conditions and a clear ventilation path around the pump. A compact footprint does not remove the need for heat dissipation or access for maintenance.
Q5: What should I check before connecting it to a process?
▼A5: Specify the target absolute pressure, measured relative to a perfect vacuum, together with the required pumping speed and operating cycle. Identify moisture, particles and other process gases so compatibility and inlet protection can be reviewed. Confirm the motor supply and flange arrangement for the chosen model.
Have more questions about this product? Click the chat icon in the bottom-right corner to contact our team.