Magnetic bearing support
The rotor is actively supported without mechanical contact during normal operation. Auxiliary bearings provide protection during specified abnormal conditions.
OIL-FREE DIRECT DRIVE · CUSTOM CONFIGURATIONS
Oil-free process air with magnetic bearings, two-stage direct drive and variable speed control. Custom configurations for your duty point.
Images show an example configuration. Final appearance and scope depend on your quotation.
Not sure which model you need? Tell us your application. We’ll help you choose.
The high-speed motor drives the centrifugal impellers directly, without a speed-increasing gearbox. Active magnetic bearings support the rotor during normal operation without oil lubrication at the bearings.
Two compression stages and intercooling are combined with variable speed control. Selection starts with your actual duty point and operating profile, so the package fits the process.



PUFCO supports custom configurations for airflow, pressure, power supply, controls and package layout. Cooling-water conditions, inlet environment and downstream air treatment are reviewed during selection.
Send us your required flow, pressure and operating hours to discuss a matched package.

The rotor is actively supported without mechanical contact during normal operation. Auxiliary bearings provide protection during specified abnormal conditions.

The motor and impellers operate on a direct-drive assembly, removing the speed-increasing gearbox and its lubrication system.

Intercooling between compression stages manages air temperature. Cooling-water temperature, flow and quality are confirmed for the selected duty.
Motor speed adjusts within the operating envelope to follow demand. The selection review includes minimum flow, control range and surge protection.
No oil is injected into the compression path. Drying, filtration and any application-specific air-quality requirements are specified separately.
The magnetic bearing system includes rotor monitoring, auxiliary bearing protection and power-loss protection. Control and communication requirements can be discussed.
Component images illustrate the operating principle; the final design and supplied scope depend on the selected configuration.
Select by required airflow and pressure, rather than power alone. The table shows 36 reference configurations; the final duty point is confirmed in the technical quotation.
On small screens, swipe the table horizontally to see all columns.
| Reference configuration | Whole-machine power (kW) | Pressure range bar(G) | Inlet flow (m³/min) | Maximum flow (m³/min) |
|---|---|---|---|---|
| 01 | 110 | 0.5–1.5 | 52 | 64 |
| 02 | 110 | 1.0–2.0 | 42 | 48 |
| 03 | 110 | 1.5–3.0 | 32 | 38 |
| 04 | 132 | 1.0–2.5 | 42 | 50 |
| 05 | 132 | 1.5–3.0 | 37 | 50 |
| 06 | 160 | 0.5–1.5 | 75 | 84 |
| 07 | 160 | 1.0–2.0 | 60 | 72 |
| 08 | 160 | 1.5–3.0 | 45 | 55 |
| 09 | 160 | 1.5–3.5 | 42 | 50 |
| 10 | 180 | 1.0–2.0 | 68 | 82 |
| 11 | 180 | 1.0–2.5 | 60 | 70 |
| 12 | 200 | 1.0–2.5 | 65 | 78 |
| 13 | 200 | 1.5–3.0 | 56 | 68 |
| 14 | 200 | 1.5–3.5 | 53 | 62 |
| 15 | 190 | 2.5–4.0 | 46 | 53 |
| 16 | 250 | 1.0–2.0 | 95 | 105 |
| 17 | 250 | 1.0–2.5 | 80 | 90 |
| 18 | 250 | 1.0–3.0 | 70 | 82 |
| 19 | 250 | 1.5–3.5 | 65 | 75 |
| 20 | 240 | 2.5–4.0 | 58 | 65 |
| 21 | 250 | 2.0–5.0 | 56 | 67 |
| 22 | 315 | 1.0–2.0 | 120 | 135 |
| 23 | 315 | 1.0–2.5 | 102 | 120 |
| 24 | 315 | 1.0–3.0 | 90 | 105 |
| 25 | 315 | 1.5–3.5 | 80 | 96 |
| 26 | 300 | 2.5–4.0 | 74 | 85 |
| 27 | 300 | 3.0–4.5 | 68 | 80 |
| 28 | 400 | 1.0–2.0 | 152 | 168 |
| 29 | 400 | 1.0–2.5 | 130 | 156 |
| 30 | 400 | 1.0–3.0 | 115 | 126 |
| 31 | 400 | 1.5–3.5 | 102 | 120 |
| 32 | 500 | 1.0–2.5 | 162 | 180 |
| 33 | 500 | 1.0–3.0 | 145 | 160 |
| 34 | 550 | 1.0–2.5 | 176 | 200 |
| 35 | 550 | 1.0–3.0 | 160 | 178 |
| 36 | 600 | 1.0–3.0 | 174 | 200 |
Air supply for aerobic fermentation, selected against vessel pressure, aeration demand, distribution losses and the required turndown. Sterile filtration is specified where the process requires it.
Oil-free compressed air for suitable production and process duties. Required particle, moisture, oil and microbiological limits are confirmed together with downstream treatment.
Continuous low-pressure air duties in chemical, textile and other manufacturing processes, where the required flow and pressure fall within the selected configuration’s operating envelope.
Share the required flow, pressure at the point of use, operating hours, inlet conditions, available power and cooling water. We will discuss the compressor, controls and air treatment as one package.
For other pressure or capacity requirements, see our industrial centrifugal air compressor range or contact us for selection.
A1: This design uses magnetic bearings and a high-speed direct-drive motor instead of a speed-increasing gearbox. The best choice depends on flow, pressure, operating profile, site utilities and service requirements; magnetic bearings alone do not determine overall efficiency.
A2: The listed configurations span 0.5–5 bar(G), with inlet flow values of 32–176 m³/min. These are ranges across different configurations, not one machine’s full operating range. We confirm a suitable configuration at your required duty point.
A3: No oil is injected into the compression path, but final air quality also depends on the inlet air, pipework, dryer and filters. Sterile or other critical process duties require a separately specified and validated treatment system. Contact us with your air-quality limits and documentation requirements.
A4: These reference configurations are water cooled. Please provide your power supply, cooling-water inlet temperature, available flow, water quality and site conditions. Connection sizes, utility consumption and electrical requirements are confirmed for the selected package.
A5: Yes. We support custom configurations based on airflow, pressure, power supply, controls, communication requirements and installation layout. The quotation identifies the compressor configuration and any selected downstream treatment or accessories.
A6: Send your required airflow and its reference conditions, discharge pressure or point-of-use pressure, operating hours, demand variation, air-quality requirements, power supply and cooling-water conditions. Factory testing can be arranged. Contact us to discuss your requirements.
Have more questions about this product? Click the chat icon in the bottom-right corner to contact our team.
We use cookies to keep this site working properly and to understand how it is used. You can accept all cookies or continue with essential ones only. Cookie policy